October 31, 2017

Why to Choose Pre-terminated Copper Trunk Cable?

For data center and enterprise deployments, pre-terminated copper trunk cable is a wonderful choice to achieve simple and quick installation. It can fit most patch panel port densities and improve better airflow and cable management. With the right upfront panning and coordination, these copper trunk cables can offer major benefits over terminating twisted-pair cables in the field. This article will take you to explore the pre-terminated copper trunk cable.

cat6 pre-terminated trunk cable

What Is Pre-terminated Copper Trunk Cable?

Pre-terminated copper trunk cable is a kind of cable which has gone through the same procedures with other cables. But their connectors have already been terminated, properly polished, and the entire cable assembly tested on either both or one end in factory. Copper trunk cables are typically comprised of bundles of 6, 8, or 12. Since they are bundled together, there is no need to worry about cable mess. Pre-terminated copper trunk cables provide a quick "plug-and-play” solution for links between switches, servers, patch panels and zone distribution areas in the data center.

Advantages of Pre-terminated Copper Trunk Cable
  • Increase speed of deployment

Compared to field terminations, pre-terminated cabling can reduce installation time by up to 75 percent.

  • Improve cable management

Pre-terminated solutions are ideal for data centers, which are designed with consistent distances between cabinets and rows.

  • Remove the need for transmission performance testing

For pre-terminated copper trunk cable, the transmission testing is performed by manufacturer before shipment.

  • Avoid time-wasting rework

Pre-terminated copper trunk cables are terminated in factory, and many of them are provided in a cassette format. This format allows installers to "plug and play” multiple connections with one cassette, which reduce installation time obviously.

copper-patch-cable-and-pre-terminated-copper-trunk-cable

Termination Types of Trunk Cable

When selecting copper trunk cables, to choose a right termination type is a very important step, which is based on the layout of the data center or telecommunications room. it's worth noting that the accessibility of the active equipment (including servers, switches, etc.) and the proper patching solution should be considered during the process of selection. Generally, there are four common termination types: jack-to-jack, jack-to-plug, plug-to-plug and jack-to-open. Different types have different requirements for installation. The following will introduce these four termination types respectively:

Jack to Jack: This termination type is typically used in cabinet-to-cabinet permanent link trunk. In general, it is installed into empty patch panels on both ends in common interconnect and cross connect architectures. The use of patch cords is used to complete the connectivity between the active equipment and the physical layer.

Jack to Plug: Typically used for in-cabinet or cabinet-to-cabinet equipment cord harnesses, the jack-to-plug type is installed into the patch panels on one end and switch ports on the other end for switch port replication applications, eliminating one cross-connect point by having the cable plug directly into the active equipment.

Plug to plug: Typically used to make a direct connection between active equipment, e.g. server to switch, eliminating cross-connect capabilities. It can also be used in an open-space work area as a bundled patch cord group.

Jack to Open: This type is similar to jack-to-jack configuration, but one end should be cut to length and field-terminated to a target termination place, such as 110-style panel, patch panel or wall plate. Field testing of the drops is necessary after the cables have been terminated in this case.

Deployment Considerations
1. Copper Cable Type

Copper trunk cables using Cat5, Cat5e, Cat6 and Cat7 cables are all available in the market.

2. Cable Count

The most commonly used copper cables usually have 6 or 12 cables in one bound. Higher or lower cable counts are also available.

3. Breakout Length

Breakout length refers to the dimension from the end of the braided sleeve to connectors at the end of the cables. This dimension is part of the overall length, not in addition to the length measurement. The primary consideration for breakout length is to have flexibility to route the cables as needed.

4. Proper Length

For pre-terminated copper trunk cable assemblies, length is a very important parameter to be ordered which help users to achieve the best performance.

length

5. PVC VS. LSZH

You must consider the fire ratings of materials to minimize danger in the event of a fire. Most data centers are a riser environment, where airflow is not a consideration. The jacket of cables is an important point when selecting pre-teminated copper trunk cables. The purpose of the jacket is to protect the wiring from physical damage, moisture, ozone and ultraviolet rays. PVC is made of polyvinyl chloride that gives off heavy black smoke, hydrochloric acid and other toxic gases when it burns. While LSZH has a flame-resistant jacket that doesn’t emit toxic fumes even if it burns. Both cables are excellent in performance, so it depends on the situation whether you choose LSZH or PVC.

FS Pre-terminated Copper Trunk Cable Solution

FS.COM provides a lot of Cat5e/Cat6/Cat7 pre-terminated trunk cable with plug-to-plug or jack-to-jack termination type. And FS.COM copper trunks include a braided mesh sleeve whose properties match that of the cable jacket. This ensures that the binding material does not degrade the suitability of the product in a plenum environment. The following table lists the main solutions.

FS P/N Cable Type Cable Color Termination Type Cable Rating Cable Count
CAT5E-U12PPBE-3M Cat5e Unshielded Blue Plug to Plug LSZH 12
CAT6-U06JJBE-10M Cat6 Unshielded Blue Jack to Jack LSZH 6
CAT6-U6PPBE-3M Cat6 Unshielded Blue Plug to Plug PVC CMR 6
CAT6-U06HQJJ-10M Cat6 Unshielded Blue Jack to Jack PVC CMR 6
CAT6A-S6PPOW-5M Cat6a Shielded Off-White Plug to Plug PVC CMR 6
Summary

Pre-terminated copper trunk cable assemblies are an ideal solution for data center infrastructures and backbone applications where cable distances are reasonably predictable and can be easily determined. They play an important role in reducing installation time and cost, helping you deploy a reliable, easy-to-use copper trunking system.

Posted by: angelina at 07:26 AM | Comments (1) | Add Comment
Post contains 977 words, total size 10 kb.

October 12, 2017

Transceiver Optics and Cable Options for HP 5820AF-24XG Switch (JG219B)

The requirements of virtualization and cloud trends are changing enterprise business environments, high port density, high throughput and very low latency are bedrock requirements in the data center. The HP 5820 switch series are built to meet these requirements, and help enterprises to reduce operating costs and build agile and resilient enterprises. As a member in the family of HP 5820 switch series, the HP 5820AF-24XG switch is a managed L3 switch supporting Gigabit Ethernet and 10 Gigabit Ethernet SFP+ optics and cables. It can serve as a leaf or access top-of-rack 10 Gigabit Ethernet switch in data centers. This article will provide the optical solutions such as fiber optic transceivers and direct attach cables that are supported by HP 5820AF-24XG switch.

HP 5820AF-24XG switch

HP 5820AF 24XG Switch JG219B

In the family of HP 5820 switch series, HP 5820AF-24XG switch (JG219B ) thus obtains several features of the series. It provides a versatile, high-performance and 1/10GbE top-of-rack data center switch architecture with deployment flexibility. The switch can be deployed for data center top-of-rack server access; or as high-performance Layer 3, 10GbE aggregation switches in campus and data center networks. JG219B offers Gigabit and 10 Gigabit connectivity. It includes 24 fixed 1000/10000 SFP+ ports and 4 RJ-45 autosensing 10/100/1000 ports. The total switching capacity of this switch can reach up to 484 Gbps supporting as much as 363mpps throughput.

HP-JG219B

Fiber Optic Transceivers and Direct Attach Cables for HP 5820AF 24XG Switch

As stated above, the HP 5820AF 24XG switch is available with 1 GbE and 10 GbE data links. The SFP transceivers, SFP+ transceivers, 10G SFP+ to SFP+ direct attach copper cables and 40G QSFP+ to 4x10G SFP+ direct attach copper breakout cables for HP 5820AF 24XG switch are shown in the following tables.

SFP Transceivers
MFG PART# Description Cable Type Interface
JD061A HP Compatible 1000BASE-LH SFP 1310nm 40km DOM Transceiver, $ 14.00 SMF LC Duplex
JD062A HP Compatible 1000BASE-LH SFP 1550nm 40km DOM Transceiver, $ 24.00 SMF LC Duplex
JD063B HP Compatible 1000BASE-LH SFP 1550nm 70km DOM Transceiver, $ 24.00 SMF LC Duplex
JD089B HP Compatible 1000BASE-T SFP Copper RJ45 100m Transceiver, $ 16.00 Cat 5 RJ45
JD118B HP Compatible 1000BASE-SX SFP 850nm 550m DOM Transceiver, $ 10.00 MMF LC Duplex
JD119B HP Compatible 1000BASE-LX SFP 1310nm 10km (SMF Distance) DOM Transceiver, $ 12.00 SMF/MMF LC Duplex
SFP+ Transceivers
MFG PART# Description Cable Type Interface
JD092B HP Compatible 10GBASE-SR SFP+ 850nm 300m DOM Transceiver, $ 16.00 MMF LC Duplex
JD093B HP Compatible 10GBASE-LRM SFP+ 1310nm 220m DOM Transceiver, $ 34.00 MMF LC Duplex
JD094B HP Compatible 10GBASE-LR SFP+ 1310nm 10km DOM Transceiver, $ 34.00 SMF LC Duplex
JG234A HP Compatible 10GBASE-ER SFP+ 1550nm 40km DOM Transceiver, $ 149.00 SMF LC Duplex
10G SFP+ to SFP+ Direct Attach Copper Cables
MFG PART# Description
JD095C 0.65m HP JD095C Compatible 10G SFP+ Passive DAC, $ 22.00
JD096C 1.2m HP Compatible 10G SFP+ Passive DAC,$ 23.00
JD097C 3m HP Compatible 10G SFP+ Passive DAC, $ 29.00
JG081C 5m HP Compatible 10G SFP+ Passive DAC, $ 56.00
40G QSFP+ to 4x10G SFP+ Direct Attach Copper Breakout Cables
MFG PART# Description
JG329A 1m HP Compatible QSFP+ to 4SFP+ Passive Breakout DAC, $ 78.00
JG330A 3m HP Compatible QSFP+ to 4SFP+ Passive Breakout DAC, $ 91.00
JG331A 5m HP Compatible QSFP+ to 4SFP+ Passive Breakout DAC, $ 120.00
Conclusion

HP 5820AF 24XG switch (JG219B) provides a simplified network architecture designed for scalability and reliability. It is a good option for 1 GbE and 10 GbE networks over buildings, campus and data centers. 

Posted by: angelina at 07:07 AM | Comments (1) | Add Comment